Production Status: Available for sale to all U.S. customers. Please check with your local Emerson Climate Technologies representative
for international availability.
HFC, R-407C, Dew Point, 50Hz, 3- Phase, 380/ 420V
ZR94KCE-TFD
Power( Watts) :
Current( Amps) :
EER( Btu/ Wh) :
Mass Flow ( lbs/ hr) : 1140.0
11.4
12.9
6950 4720
10.3
20.0
1175.0
Overall Length( in) :
Overall Width ( in) :
Overall Height ( in) :
11.23
18.75
7.5
7.5
Mounting Height( in) : 19.5*
Mounting Width( in) :
Mounting Length( in) : 10.38
0.0 Stroke ( in) :
94500 78600 Capacity( Btu/ hr) :
Bore Size ( in) : 0.0 Displ( ft^ 3/ hr) : 781.1840
7.758 Displ( in^ 3/ Rev) : 0 Number of Cylinders:
65/ 85 65/ 115
Mechanical Performance
Sound Power( dBA) :
Vibration( mils( peak-peak) ) :
74Ave 79Max
3.0Ave 4.5Max 85
81 Oil Recharge( oz) :
Initial Oil Charge ( oz) :
Discharge Size( in) :
Suction Size ( in) :
126.0 Net Weight( lbs) :
2900
23.0 MCC ( Amps) :
RPM:
LR3104C CSA File No.:
95.0
LRA-Half Winding:
LRA-High* :
LRA-Low* : 86.0
UL File Date: 27-Sep-1996
SA-2337 UL File No.:
Electrical
Max Operating Current: 15.9
45/ 100 45/ 130
7/ 8 Stub
1 1/ 8 Stub
Air Conditioning
Evap( ° F) / Cond( ° F)
RG( ° F) / Liq( ° F)
639.0 Internal Free Volume( in^ 3) :
*
HorsePower 8.0
* Low and High refer to the low and high nominal voltage ranges for which the motor is approved.
Overall compressor height on Copeland Brand Product' s specified
mounting grommets.
RLA( = MCC/ 1.4; use for contactor selection) : 16.4
RLA ( = MCC/ 1.56; use for breaker & wire size selection) : 14.7
2007-12-06 Record Date:
Alternate Applications
Application Voltage Phase Refrigerant Frequency( Hz)
460 3 R-134a HFC 60 Air Conditioning
460 3 R-407C HFC 60 Air Conditioning
380/ 420 3 R-134a HFC 50 Air Conditioning
Thai Nair Equipment, Tel 02-282-3822, 281-6295.
Page 1 of 1
5/ 18/ 2009