Production Status: Available for sale to all U.S. customers. Please check with your local Emerson Climate Technologies representative
for international availability.
HFC, R-407C, Dew Point, 50Hz, 3- Phase, 380/ 420V
ZR40K3E-TFD
Power( Watts) :
Current( Amps) :
EER( Btu/ Wh) :
Mass Flow ( lbs/ hr) : 461.0
10.7
5.4
2960 1940
4.1
19.8
475.0
Overall Length( in) :
Overall Width ( in) :
Overall Height ( in) :
9.567
15.729
7.5
7.5
Mounting Height( in) : 15.965*
Mounting Width( in) :
Mounting Length( in) : 9.567
0.0 Stroke ( in) :
38300 31700 Capacity( Btu/ hr) :
Bore Size ( in) : 0.0 Displ( ft^ 3/ hr) : 333.1964
3.309 Displ( in^ 3/ Rev) : 0 Number of Cylinders:
65/ 85 65/ 115
Mechanical Performance
Sound Power( dBA) :
Vibration( mils( peak-peak) ) :
68Ave 73Max
2.0Ave 3.0Max 42
38 Oil Recharge( oz) :
Initial Oil Charge ( oz) :
Discharge Size( in) :
Suction Size ( in) :
62.0 Net Weight( lbs) :
2900
9.0 MCC ( Amps) :
RPM:
CSA File No.:
46.0
LRA-Half Winding:
LRA-High* :
LRA-Low* : 41.0
UL File Date: 14-Jun-1994
UL File No.:
Electrical
Max Operating Current: 7.0
45/ 100 45/ 130
1/ 2 Stub
3/ 4 Stub
Air Conditioning
Evap( ° F) / Cond( ° F)
RG( ° F) / Liq( ° F)
191.0 Internal Free Volume( in^ 3) :
*
HorsePower
* Low and High refer to the low and high nominal voltage ranges for which the motor is approved.
Overall compressor height on Copeland Brand Product' s specified
mounting grommets.
RLA( = MCC/ 1.4; use for contactor selection) : 6.4
RLA ( = MCC/ 1.56; use for breaker & wire size selection) : 5.8
2005-04-15 Record Date:
Alternate Applications
Application Voltage Phase Refrigerant Frequency( Hz)
460 3 R-134a HFC 60 Air Conditioning
460 3 R-407C HFC 60 Air Conditioning
380/ 420 3 R-134a HFC 50 Air Conditioning
Thai Nair Equipment, Tel 02-282-3822, 281-6295.